Resistive&Inductive(RL) Load Bank

OREN-Resistive&Inductive(RL) Load Bank is mainly used for Generator testing at power station, AC power supply, data center and other testing,May detect the performance of different loads of the AC power supply of the power station.The power input is uniformly optimized to meet the needs of different loads.

Send enquiry
Product details

Resistive&Inductive(RL) Load Bank

OREN-Resistive&Inductive(RL) Load Bank is mainly used for Generator testing at power station, AC power supply, data center and other testing,May detect the performance of different loads of the AC power supply of the power station.The power input is uniformly optimized to meet the needs of different loads.

Technical Specifications

Models

AC230V-10kW-RL

AC480V-30kW-RL

AC480V-60kW-RL

AC480V- 100kW-RL

AC480V-200kW-RL

AC480V-500kW-RL

Capacity

Resistive load:

10kW

Inductive load:

25kVAR

Resistive load:

30kW

Inductive load:

22.5kVAR

Resistive load:

60kW

Inductive load:

45kVAR

Resistive load:

100kW

Inductive load:

75kVAR

Resistive load:

200kW

Inductive load:

150kVAR

Resistive load:

500kW

Inductive load:

375kVA


Rated

Voltage

Single Phase,

AC230V

Three Phase AC480V,

or units can be specified by customer

Customized solutions could be available upon request.

Rated        current at 480VAC

Resistive amperes

per phase: 26A

Reactive amperes

per phase: 20A

Resistive amperes

per phase: 36A

Reactive amperes

per phase: 27A

Resistive amperes

per phase: 72A

Reactive amperes

per phase: 54A

Resistive amperes

per phase: 120A

Reactive amperes

per phase: 90A

Resistive amperes

per phase: 240A

Reactive amperes

per phase: 180A

Resistive amperes

per phase: 601A

Reactive amperes

per phase: 451A

PF

PF=0.8(or customized power factor)

Minimum

Load Step

100W , 100VAR

100W , 100VAR

100W , 100VAR

1kW , 1kVAR

1kW , 1kVAR

1kW , 1kVAR

Display

Voltage, Current, Frequency, Power and PF displayed by digital meter

Protection

Overheating alarm, Short circuit protection, Overheating protection, Fan overloading protection, Emergency stop button. All protections can be configured optionally

Control

Mode

Manual control by MCBs or push buttons

Air Flow

Horizontal, Force-air cooling

Dimension

48*60*27(cm)

90*90*160(cm)

90*90*200(cm)

120*120*200(cm)

90*90*200(cm)

120*120*200(cm)