中文简体 English

Telephone: ++86 029-68229739

E-mail: sales@oren-electric.com

Current location: Home > Product > Contents

OREN-AC380V-200KW-R Resistive AC Load Bank

It is really critical that your standby power system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc working in good condition if switched to be loaded when the main power supply in maintenance procedure or stop abnormally. Downtime could be reduced by regular maintenance and thorough inspections which are the key to power supply systems maintenance.

Send enquiry
Product details

OREN-AC380V-200KW-R Resistive AC Load Bank

Why need load bank testing

It is really critical that your standby power system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc working in good condition if switched to be loaded when the main power supply in maintenance procedure or stop abnormally. Downtime could be reduced by regular maintenance and thorough inspections which are the key to power supply systems maintenance.

 Critical power backup equipment like UPS System and generator which especially located in harsh, dusty or corrosive environment will fail without proper preventative maintenance. OREN provides a whole range of custom preventative maintenance products solutions for UPS systems and generators and many more to ensure constant uptime for your power systems and make you prepared for anything.

 Load banks help highlight a large range of faults on the equipment it tests. The first objective when testing with an electric bank is to ensure your equipment’s power supply is reliable. The underlying question that needs answering is whether your equipment will have sufficient power supply to ensure uninterrupted operational performance. The load bank also tests that the equipment is not faulty, that there are no faults in construction, that the aging of the equipment is in line with expectations, that the components are reliable and that there are no pending breakdowns or early signs of wear and tear. The load bank also ensures that the product delivers power conform to its specification.

 OREN series AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively, which includes (click to view more):

A、RCD AC Load Bank(RCD)

B、Pure Resistive AC Load Bank(R)

C、Rack Mounted AC/DC Load Bank

D、Resistive and Inductive AC Load Bank(RL)

E、Resistive, Inductive and Capacitive AC Load Bank(RLC)

 About OREN load banks resistor

Highly reliable and durable new alloy resistor is used for the OREN’s AC & DC load bank. It is thermal shrinkable and seal installed in the stainless steel pipe, whose surface with insulated heat sink. The resistor is moisture-proof, anti-corrosion, good heat dissipation, high insulation resistance, safe and reliable.Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.

 OREN load bank control modes

Two control modes available for OREN AC load banks: The local panel control mode and the remote control mode by PLC through PC software. Local control mode will be locked once load bank is switched to remote control mode. By applying the PLC, we could make load bank an intelligent test system, load power curve could be preset through PC software and all electrical parameters of EUT(equipment under test) including current, voltage, apparent power, active power, reactive power, power factor, frequency and warning info could be achieved automatically by the PC software and displayed by load bank digital meter. Up to 15 load banks at most could be parallel controlled by PC software which generating the test tables, curves and standard test report.


Technical Specifications

Model

OREN-AC380V-200KW-R Resistive AC Load Bank

Load Element

Alloy resistors

Load Voltage

AC380V 3 phase 4 wire

Load Power

200KW for AC380V 3 Phase 4 Wire

Load Steps

13 Load Steps (three phase controlled):

100W/200W/200W/500W/1KW/2KW/2KW/4KW/10KW/20KW/20KW/40KW/100KW

Power Factor

PF=1

Load Accuracy

±5%

Digital Meter

Voltage, Current, Power, Frequency and etc.

Power Supply

220V(±10%) 50HZ, single phase

Control Mode

Manual control by circuit breakers and push button

Wire Connections

Internal terminal for wire connections

(wires in/out down cabinet)

Insulation Class

F

Protection Level

IP20(indoor use

Fan Noise

75dB

Cooling Mode

Force-air cooling

Work Mode

Continuous work

Protections

Overheating/buzzer alarm, short circuit protection, overheating/over current & voltage protection, emergency stop button

Ambient Temperature

-10+50

Dimension

800*1200*1750mm

Weight

250KG

Mobility

Four wheels, lifting rings in chassis top

Humidity

≤95%

Altitude

≤2500 meters

Note:

Ø  Remote control function is optional

Ø  AC & DC load voltage could be made compatible in ONLY one unit with several different load voltages.

In some countries, 220V 1P will be replaced by 120V/230V/240V/277V 1P, 380V 3P will be replaced by 208V/400V/415V/480V 3P. Resistive AC load bank for load voltage 208V 3P and 120V 1P, 415V 3P and 240V 1P, 480V 3P and 277V 1P with higher load power are also available as per your need.


Related products
Inquiries